<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://lab.kni.caltech.edu/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Jpalmer</id>
	<title>The KNI Lab at Caltech - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://lab.kni.caltech.edu/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Jpalmer"/>
	<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/Special:Contributions/Jpalmer"/>
	<updated>2026-04-16T03:26:29Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.41.5</generator>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=3375</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=3375"/>
		<updated>2024-01-29T20:24:58Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&amp;lt;br&amp;gt;Member of the Professional Staff&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alireza Ghaffari&lt;br /&gt;
|JobTitle = KNI Laboratory Staff&amp;lt;br&amp;gt;Member of the Professional Staff&lt;br /&gt;
|CaltechID = alireza&lt;br /&gt;
|Office = 176 Watson&lt;br /&gt;
|Phone = 626-395-3984 (office)&amp;lt;br&amp;gt;&lt;br /&gt;
|AreasResponsibility = Foundry, AFM, photolithography, support tools&lt;br /&gt;
|Photo = Coming Soon&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Kelly McKenzie&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = Plasma etch / deposition,&amp;lt;br&amp;gt;Tube furnaces&lt;br /&gt;
|Photo = McKenzie_Kelly_2.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=3374</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=3374"/>
		<updated>2024-01-29T20:24:18Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Laser Interference Lithography Room&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alireza Ghaffari | Ghaffari, Alireza]]&lt;br /&gt;
|StaffOfficeNumber = 176 Watson&lt;br /&gt;
|StaffOfficePhone = 3984&lt;br /&gt;
|CaltechID = ghaffari&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Kelly McKenzie | McKenzie, Kelly]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=3369</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=3369"/>
		<updated>2024-01-11T19:18:52Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&amp;lt;br&amp;gt;Member of the Professional Staff&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alireza Ghaffari&lt;br /&gt;
|JobTitle = KNI Laboratory Staff&amp;lt;br&amp;gt;Member of the Professional Staff&lt;br /&gt;
|CaltechID = alireza&lt;br /&gt;
|Office = 176 Watson&lt;br /&gt;
|Phone = 626-395-3984 (office)&amp;lt;br&amp;gt;&lt;br /&gt;
|AreasResponsibility = Foundry, AFM, photolithography, support tools&lt;br /&gt;
|Photo = Coming Soon&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Kelly McKenzie&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = Plasma etch / deposition,&amp;lt;br&amp;gt;Tube furnaces&lt;br /&gt;
|Photo = McKenzie_Kelly_2.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=3368</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=3368"/>
		<updated>2024-01-11T19:18:21Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Call the Staff */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Laser Interference Lithography Room&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alireza Ghaffari | Ghaffari, Alireza]]&lt;br /&gt;
|StaffOfficeNumber = 176 Watson&lt;br /&gt;
|StaffOfficePhone = 3984&lt;br /&gt;
|CaltechID = ghaffari&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Kelly McKenzie | McKenzie, Kelly]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3338</id>
		<title>Usage Rates</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3338"/>
		<updated>2023-10-10T23:58:09Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Overview of KNI Lab User Fees&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;Rates below are valid beginning October 1, 2023 and are subject to change&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* Fees are incurred on a pay-as-you-go basis (tools are charged by the hour or portion thereof).&lt;br /&gt;
* Caltech/JPL/Academic or Government lab members are &#039;&#039;&#039;NOT&#039;&#039;&#039; charged any Lab fees during days or months of non-use&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note: New users must submit a [[Membership_Forms | New User Form]] and attend general KNI Lab safety training before lab access or further tool training is allowed.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Caltech &amp;amp; JPL Usage Rates ==&lt;br /&gt;
Below is a table of &#039;&#039;direct&#039;&#039; hourly rates for lab and equipment use in the KNI Laboratory. Hourly rates are applied to an individual&#039;s actual usage in the KNI Lab. Discounted hourly rates are &amp;quot;unlocked&amp;quot; for hours that exceed the thresholds listed below. Tier C indicates the maxiumum number of hours a user will be charged in a given calendar month. Rates shown below do not include F&amp;amp;A/overhead. Overhead will be applied separately based on the PTA. Customers will be invoiced on a quarterly basis. Rates are valid beginning October 1, 2023 and are subject to change. &lt;br /&gt;
Rates below apply to internal Caltech or JPL users.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 80%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 50%&amp;quot;| Equipment Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 35%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15%&amp;quot; | Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | General KNI Lab Use*&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Dielectric System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford DRIE System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford III-V System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Plasmatherm Reactive Ion Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford FlexAl ALD/ALE System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford PECVD System 100&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Chalcogenide Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Dielectric Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA E-beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| CHA MK40 E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Lesker Labline E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 600 Dualbeam Focused Ion Beam&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Atomic Force Microscope&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Zeiss Orion NanoFab&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 200 NanoLab Dualbeam SEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Quanta ESEM /NPGS&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Sirion FESEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF-30 TEM, STEM, EDS &amp;amp; HAADF &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $140&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Nanoscribe Photonic Professional GT&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 3D Printer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;General Lab Use is counted as time in the KNI cleanroom facility. It includes access to:&#039;&#039;&#039; &lt;br /&gt;
- Critical Point Dryer&lt;br /&gt;
- Laser Interference Lithography System&lt;br /&gt;
- Mask Aligners&lt;br /&gt;
- Parylene Coater&lt;br /&gt;
- Profilometer&lt;br /&gt;
- Scriber Breaker&lt;br /&gt;
- Spectroscopic Ellipsometer&lt;br /&gt;
- Tube Furnaces (Wet, Dry Oxide + Annealing)&lt;br /&gt;
- Wafer Bonder&lt;br /&gt;
- Wafer Stepper&lt;br /&gt;
- Wet Chemistry Room/general chemical supplies&lt;br /&gt;
- Wire Bonder&lt;br /&gt;
- XeF2 Silicon Etcher&lt;br /&gt;
- TEM prep area (in Keck)&lt;br /&gt;
- Other tools not listed in the table above&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Miscellaneous Rates&#039;&#039;&#039;&lt;br /&gt;
*Precious Metal (gold and platinum) usage will be billed the market rate, per gram.&lt;br /&gt;
*Dedicated KNI Staff Labor/Support for Research is $100/hr.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;MONTHLY TIERED RATES&#039;&#039;&#039; &lt;br /&gt;
Discounts are applied on an individual user basis for hours accrued in a specific Lab Area during a given calendar month.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 28%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier A&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier A Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier B&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier B Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier C&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier C Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $24&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $32.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 8 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 8-16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $7.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 12 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 12-24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $36.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 12 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 12-24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $18.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $130&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| NA&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| NA&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| &lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 64-128 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $6&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 128 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab Use&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 32-64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Example:&#039;&#039;&#039;&lt;br /&gt;
A lab member logs 35 cumulative hours on the Lesker e-beam evaporator and the AJA dielectric sputterer in the month of October. Based on the&lt;br /&gt;
thresholds listed above for the &amp;quot;Physical Deposition&amp;quot; Area (which includes the Lesker and AJA tools), the costs are:&lt;br /&gt;
(16 hours x $35) + (16 hours x $17.50) + (3 hours x $0) = $840 for 35 hours.&lt;br /&gt;
During that same calendar month, the same user logs 60 total hours in the general KNI lab facility and 5 hours on the spectroscopic ellipsometer,&lt;br /&gt;
which is included in the &amp;quot;General Lab&amp;quot; Area. Those costs are:&lt;br /&gt;
(32 hours x $35) + (28 hours x $17.50) = $1,610 for 60 hours.&lt;br /&gt;
The lab member&#039;s total October direct costs are $2,450.&lt;br /&gt;
&lt;br /&gt;
==OVERHEAD/INDIRECT COST RATE==&lt;br /&gt;
*Non-Caltech Academic, Government, and Corporate KNI lab members will be subject to Caltech&#039;s F&amp;amp;A (indirect/&amp;quot;overhead&amp;quot;) costs. The F&amp;amp;A rate for fiscal year 2024 is 70%. &lt;br /&gt;
Internal (Caltech and JPL) users will also have overhead applied to their charges. The overhead is accounted for in the back end of the internal charging process and the overhead rate is dependent on the PTA used to pay for the KNI Lab fees. If you have questions about this, please check with your grants manager.*&lt;br /&gt;
&lt;br /&gt;
==External/Corporate Memberships==&lt;br /&gt;
&lt;br /&gt;
For information on the KNI corporate lab membership plan, please send an email to [mailto:tkimoto@caltech.edu tkimoto@caltech.edu] with details regarding 1) the number of people looking to join as KNI lab members, 2) equipment needs, 3) anticipated start date, and 4) information about the company. Startup companies may qualify for limited-term reduced rates. Additional paperwork is required, including a Facilities Use Agreement, purchase order, and an External Affiliate appointment. This process may take a few weeks before an external user is able to start in the KNI Lab.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3337</id>
		<title>Usage Rates</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3337"/>
		<updated>2023-10-10T21:48:22Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* OVERHEAD/INDIRECT COST RATE */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Overview of KNI Lab User Fees&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;Rates below are valid beginning October 1, 2022 and are subject to change&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* Fees are incurred on a pay-as-you-go basis (tools are charged by the hour or portion thereof).&lt;br /&gt;
* Caltech/JPL/Academic or Government lab members are &#039;&#039;&#039;NOT&#039;&#039;&#039; charged any Lab fees during days or months of non-use&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note: New users must submit a [[Membership_Forms | New User Form]] and attend general KNI Lab safety training before lab access or further tool training is allowed.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Caltech &amp;amp; JPL Usage Rates ==&lt;br /&gt;
Below is a table of &#039;&#039;direct&#039;&#039; hourly rates for lab and equipment use in the KNI Laboratory. Hourly rates are applied to an individual&#039;s actual usage in the KNI Lab. Discounted hourly rates are &amp;quot;unlocked&amp;quot; for hours that exceed the thresholds listed below. Tier C indicates the maxiumum number of hours a user will be charged in a given calendar month. Rates shown below do not include F&amp;amp;A/overhead. Overhead will be applied separately based on the PTA. Customers will be invoiced on a quarterly basis. Rates are valid beginning October 1, 2022 and are subject to change upon review at the end of FY23 Q2. &lt;br /&gt;
Rates below apply to internal Caltech or JPL users.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 80%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 50%&amp;quot;| Equipment Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 35%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15%&amp;quot; | Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | General KNI Lab Use*&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Dielectric System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford DRIE System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford III-V System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Plasmatherm Reactive Ion Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford FlexAl ALD/ALE System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford PECVD System 100&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Chalcogenide Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Dielectric Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA E-beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| CHA MK40 E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Lesker Labline E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 600 Dualbeam Focused Ion Beam&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Atomic Force Microscope&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Zeiss Orion NanoFab&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 200 NanoLab Dualbeam SEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Quanta ESEM /NPGS&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Sirion FESEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF-30 TEM, STEM, EDS &amp;amp; HAADF &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $140&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Nanoscribe Photonic Professional GT&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 3D Printer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;General Lab Use is counted as time in the KNI cleanroom facility. It includes access to:&#039;&#039;&#039; &lt;br /&gt;
- Critical Point Dryer&lt;br /&gt;
- Laser Interference Lithography System&lt;br /&gt;
- Mask Aligners&lt;br /&gt;
- Parylene Coater&lt;br /&gt;
- Profilometer&lt;br /&gt;
- Scriber Breaker&lt;br /&gt;
- Spectroscopic Ellipsometer&lt;br /&gt;
- Tube Furnaces (Wet, Dry Oxide + Annealing)&lt;br /&gt;
- Wafer Bonder&lt;br /&gt;
- Wafer Stepper&lt;br /&gt;
- Wet Chemistry Room/general chemical supplies&lt;br /&gt;
- Wire Bonder&lt;br /&gt;
- XeF2 Silicon Etcher&lt;br /&gt;
- TEM prep area (in Keck)&lt;br /&gt;
- Other tools not listed in the table above&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Miscellaneous Rates&#039;&#039;&#039;&lt;br /&gt;
*Precious Metal (gold and platinum) usage will be billed the market rate, per gram.&lt;br /&gt;
*Dedicated KNI Staff Labor/Support for Research is $100/hr.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;MONTHLY TIERED RATES&#039;&#039;&#039; &lt;br /&gt;
Discounts are applied on an individual user basis for hours accrued in a specific Lab Area during a given calendar month.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 28%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier A&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier A Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier B&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier B Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier C&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier C Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $24&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $32.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 8 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 8-16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $7.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 12 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 12-24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $36.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 12 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 12-24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $18.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $130&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| NA&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| NA&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| &lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 64-128 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $6&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 128 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab Use&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 32-64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Example:&#039;&#039;&#039;&lt;br /&gt;
A lab member logs 35 cumulative hours on the Lesker e-beam evaporator and the AJA dielectric sputterer in the month of October. Based on the&lt;br /&gt;
thresholds listed above for the &amp;quot;Physical Deposition&amp;quot; Area (which includes the Lesker and AJA tools), the costs are:&lt;br /&gt;
(16 hours x $35) + (16 hours x $17.50) + (3 hours x $0) = $840 for 35 hours.&lt;br /&gt;
During that same calendar month, the same user logs 60 total hours in the general KNI lab facility and 5 hours on the spectroscopic ellipsometer,&lt;br /&gt;
which is included in the &amp;quot;General Lab&amp;quot; Area. Those costs are:&lt;br /&gt;
(32 hours x $35) + (28 hours x $17.50) = $1,610 for 60 hours.&lt;br /&gt;
The lab member&#039;s total October direct costs are $2,450.&lt;br /&gt;
&lt;br /&gt;
==OVERHEAD/INDIRECT COST RATE==&lt;br /&gt;
*Non-Caltech Academic, Government, and Corporate KNI lab members will be subject to Caltech&#039;s F&amp;amp;A (indirect/&amp;quot;overhead&amp;quot;) costs. The F&amp;amp;A rate for fiscal year 2024 is 70%. &lt;br /&gt;
Internal (Caltech and JPL) users will also have overhead applied to their charges. The overhead is accounted for in the back end of the internal charging process and the overhead rate is dependent on the PTA used to pay for the KNI Lab fees. If you have questions about this, please check with your grants manager.*&lt;br /&gt;
&lt;br /&gt;
==External/Corporate Memberships==&lt;br /&gt;
&lt;br /&gt;
For information on the KNI corporate lab membership plan, please send an email to [mailto:tkimoto@caltech.edu tkimoto@caltech.edu] with details regarding 1) the number of people looking to join as KNI lab members, 2) equipment needs, 3) anticipated start date, and 4) information about the company. Startup companies may qualify for limited-term reduced rates. Additional paperwork is required, including a Facilities Use Agreement, purchase order, and an External Affiliate appointment. This process may take a few weeks before an external user is able to start in the KNI Lab.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3336</id>
		<title>Usage Rates</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3336"/>
		<updated>2023-10-10T21:48:05Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Caltech &amp;amp; JPL Usage Rates */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Overview of KNI Lab User Fees&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;Rates below are valid beginning October 1, 2022 and are subject to change&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* Fees are incurred on a pay-as-you-go basis (tools are charged by the hour or portion thereof).&lt;br /&gt;
* Caltech/JPL/Academic or Government lab members are &#039;&#039;&#039;NOT&#039;&#039;&#039; charged any Lab fees during days or months of non-use&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note: New users must submit a [[Membership_Forms | New User Form]] and attend general KNI Lab safety training before lab access or further tool training is allowed.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Caltech &amp;amp; JPL Usage Rates ==&lt;br /&gt;
Below is a table of &#039;&#039;direct&#039;&#039; hourly rates for lab and equipment use in the KNI Laboratory. Hourly rates are applied to an individual&#039;s actual usage in the KNI Lab. Discounted hourly rates are &amp;quot;unlocked&amp;quot; for hours that exceed the thresholds listed below. Tier C indicates the maxiumum number of hours a user will be charged in a given calendar month. Rates shown below do not include F&amp;amp;A/overhead. Overhead will be applied separately based on the PTA. Customers will be invoiced on a quarterly basis. Rates are valid beginning October 1, 2022 and are subject to change upon review at the end of FY23 Q2. &lt;br /&gt;
Rates below apply to internal Caltech or JPL users.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 80%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 50%&amp;quot;| Equipment Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 35%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15%&amp;quot; | Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | General KNI Lab Use*&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Dielectric System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford DRIE System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford III-V System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Plasmatherm Reactive Ion Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford FlexAl ALD/ALE System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford PECVD System 100&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Chalcogenide Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Dielectric Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA E-beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| CHA MK40 E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Lesker Labline E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 600 Dualbeam Focused Ion Beam&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Atomic Force Microscope&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Zeiss Orion NanoFab&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 200 NanoLab Dualbeam SEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Quanta ESEM /NPGS&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Sirion FESEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF-30 TEM, STEM, EDS &amp;amp; HAADF &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $140&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Nanoscribe Photonic Professional GT&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 3D Printer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;General Lab Use is counted as time in the KNI cleanroom facility. It includes access to:&#039;&#039;&#039; &lt;br /&gt;
- Critical Point Dryer&lt;br /&gt;
- Laser Interference Lithography System&lt;br /&gt;
- Mask Aligners&lt;br /&gt;
- Parylene Coater&lt;br /&gt;
- Profilometer&lt;br /&gt;
- Scriber Breaker&lt;br /&gt;
- Spectroscopic Ellipsometer&lt;br /&gt;
- Tube Furnaces (Wet, Dry Oxide + Annealing)&lt;br /&gt;
- Wafer Bonder&lt;br /&gt;
- Wafer Stepper&lt;br /&gt;
- Wet Chemistry Room/general chemical supplies&lt;br /&gt;
- Wire Bonder&lt;br /&gt;
- XeF2 Silicon Etcher&lt;br /&gt;
- TEM prep area (in Keck)&lt;br /&gt;
- Other tools not listed in the table above&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Miscellaneous Rates&#039;&#039;&#039;&lt;br /&gt;
*Precious Metal (gold and platinum) usage will be billed the market rate, per gram.&lt;br /&gt;
*Dedicated KNI Staff Labor/Support for Research is $100/hr.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;MONTHLY TIERED RATES&#039;&#039;&#039; &lt;br /&gt;
Discounts are applied on an individual user basis for hours accrued in a specific Lab Area during a given calendar month.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 28%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier A&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier A Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier B&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier B Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier C&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier C Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $24&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $32.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 8 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 8-16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $7.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 12 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 12-24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $36.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 12 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 12-24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $18.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $130&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| NA&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| NA&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| &lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 64-128 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $6&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 128 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab Use&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 32-64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Example:&#039;&#039;&#039;&lt;br /&gt;
A lab member logs 35 cumulative hours on the Lesker e-beam evaporator and the AJA dielectric sputterer in the month of October. Based on the&lt;br /&gt;
thresholds listed above for the &amp;quot;Physical Deposition&amp;quot; Area (which includes the Lesker and AJA tools), the costs are:&lt;br /&gt;
(16 hours x $35) + (16 hours x $17.50) + (3 hours x $0) = $840 for 35 hours.&lt;br /&gt;
During that same calendar month, the same user logs 60 total hours in the general KNI lab facility and 5 hours on the spectroscopic ellipsometer,&lt;br /&gt;
which is included in the &amp;quot;General Lab&amp;quot; Area. Those costs are:&lt;br /&gt;
(32 hours x $35) + (28 hours x $17.50) = $1,610 for 60 hours.&lt;br /&gt;
The lab member&#039;s total October direct costs are $2,450.&lt;br /&gt;
&lt;br /&gt;
==OVERHEAD/INDIRECT COST RATE==&lt;br /&gt;
*Non-Caltech Academic, Government, and Corporate KNI lab members will be subject to Caltech&#039;s F&amp;amp;A (indirect/&amp;quot;overhead&amp;quot;) costs. The F&amp;amp;A rate for fiscal year 2023 is 70%. &lt;br /&gt;
Internal (Caltech and JPL) users will also have overhead applied to their charges. The overhead is accounted for in the back end of the internal charging process and the overhead rate is dependent on the PTA used to pay for the KNI Lab fees. If you have questions about this, please check with your grants manager.*&lt;br /&gt;
&lt;br /&gt;
==External/Corporate Memberships==&lt;br /&gt;
&lt;br /&gt;
For information on the KNI corporate lab membership plan, please send an email to [mailto:tkimoto@caltech.edu tkimoto@caltech.edu] with details regarding 1) the number of people looking to join as KNI lab members, 2) equipment needs, 3) anticipated start date, and 4) information about the company. Startup companies may qualify for limited-term reduced rates. Additional paperwork is required, including a Facilities Use Agreement, purchase order, and an External Affiliate appointment. This process may take a few weeks before an external user is able to start in the KNI Lab.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3335</id>
		<title>Usage Rates</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3335"/>
		<updated>2023-10-10T21:28:14Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Caltech &amp;amp; JPL Usage Rates */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Overview of KNI Lab User Fees&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;Rates below are valid beginning October 1, 2022 and are subject to change&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* Fees are incurred on a pay-as-you-go basis (tools are charged by the hour or portion thereof).&lt;br /&gt;
* Caltech/JPL/Academic or Government lab members are &#039;&#039;&#039;NOT&#039;&#039;&#039; charged any Lab fees during days or months of non-use&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note: New users must submit a [[Membership_Forms | New User Form]] and attend general KNI Lab safety training before lab access or further tool training is allowed.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Caltech &amp;amp; JPL Usage Rates ==&lt;br /&gt;
Below is a table of &#039;&#039;direct&#039;&#039; hourly rates for lab and equipment use in the KNI Laboratory. Hourly rates are applied to an individual&#039;s actual usage in the KNI Lab. Discounted hourly rates are &amp;quot;unlocked&amp;quot; for hours that exceed the thresholds listed below. Tier C indicates the maxiumum number of hours a user will be charged in a given calendar month. Rates shown below do not include F&amp;amp;A/overhead. Overhead will be applied separately based on the PTA. Customers will be invoiced on a quarterly basis. Rates are valid beginning October 1, 2022 and are subject to change upon review at the end of FY23 Q2. &lt;br /&gt;
Rates below apply to internal Caltech or JPL users.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 80%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 50%&amp;quot;| Equipment Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 35%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15%&amp;quot; | Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | General KNI Lab Use*&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Dielectric System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford DRIE System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford III-V System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Plasmatherm Reactive Ion Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford FlexAl ALD/ALE System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford PECVD System 100&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Chalcogenide Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Dielectric Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA E-beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| CHA MK40 E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Lesker Labline E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 600 Dualbeam Focused Ion Beam&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Atomic Force Microscope&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Zeiss Orion NanoFab&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 200 NanoLab Dualbeam SEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Quanta ESEM /NPGS&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Sirion FESEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF-30 TEM, STEM, EDS &amp;amp; HAADF &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $140&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Nanoscribe Photonic Professional GT&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 3D Printer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;General Lab Use is counted as time in the KNI cleanroom facility. It includes access to:&#039;&#039;&#039; &lt;br /&gt;
- Atomic Force Microscope (AFM)&lt;br /&gt;
- Critical Point Dryer&lt;br /&gt;
- Laser Interference Lithography System&lt;br /&gt;
- Mask Aligners&lt;br /&gt;
- Parylene Coater&lt;br /&gt;
- Profilometer&lt;br /&gt;
- Scriber Breaker&lt;br /&gt;
- Spectroscopic Ellipsometer&lt;br /&gt;
- Tube Furnaces (Wet, Dry Oxide + Annealing)&lt;br /&gt;
- Wafer Bonder&lt;br /&gt;
- Wafer Stepper&lt;br /&gt;
- Wet Chemistry Room/general chemical supplies&lt;br /&gt;
- Wire Bonder&lt;br /&gt;
- XeF2 Silicon Etcher&lt;br /&gt;
- TEM prep area (in Keck)&lt;br /&gt;
- Other tools not listed in the table above&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Miscellaneous Rates&#039;&#039;&#039;&lt;br /&gt;
*Precious Metal (gold and platinum) usage will be billed the market rate, per gram.&lt;br /&gt;
*Dedicated KNI Staff Labor/Support for Research is $100/hr.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;MONTHLY TIERED RATES&#039;&#039;&#039; &lt;br /&gt;
Discounts are applied on an individual user basis for hours accrued in a specific Lab Area during a given calendar month.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 28%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier A&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier A Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier B&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier B Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier C&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier C Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 15 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $45&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 15-30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $22.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 10 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 10-20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 10 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 10-20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 15 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 15-30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 15 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 15-30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $130&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 50 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 50-100 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $7.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 100 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab Use&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 32-64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $18.75&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Example:&#039;&#039;&#039;&lt;br /&gt;
A lab member logs 25 cumulative hours on the Lesker e-beam evaporator and the AJA dielectric sputterer in the month of October. Based on the&lt;br /&gt;
thresholds listed above for the &amp;quot;Physical Deposition&amp;quot; Area (which includes the Lesker and AJA tools), the costs are:&lt;br /&gt;
(10 hours x $30) + (10 hours x $15) + (5 hours x $0) = $450 for 25 hours.&lt;br /&gt;
During that same calendar month, the same user logs 40 total hours in the general KNI lab facility and 5 hours on the spectroscopic ellipsometer,&lt;br /&gt;
which is included in the &amp;quot;General Lab&amp;quot; Area. Those costs are:&lt;br /&gt;
(32 hours x $37.50) + (8 hours x $18.75) = $1,350 for 40 hours.&lt;br /&gt;
The lab member&#039;s total October direct costs are $1,800.&lt;br /&gt;
&lt;br /&gt;
==OVERHEAD/INDIRECT COST RATE==&lt;br /&gt;
*Non-Caltech Academic, Government, and Corporate KNI lab members will be subject to Caltech&#039;s F&amp;amp;A (indirect/&amp;quot;overhead&amp;quot;) costs. The F&amp;amp;A rate for fiscal year 2023 is 70%. &lt;br /&gt;
Internal (Caltech and JPL) users will also have overhead applied to their charges. The overhead is accounted for in the back end of the internal charging process and the overhead rate is dependent on the PTA used to pay for the KNI Lab fees. If you have questions about this, please check with your grants manager.*&lt;br /&gt;
&lt;br /&gt;
==External/Corporate Memberships==&lt;br /&gt;
&lt;br /&gt;
For information on the KNI corporate lab membership plan, please send an email to [mailto:tkimoto@caltech.edu tkimoto@caltech.edu] with details regarding 1) the number of people looking to join as KNI lab members, 2) equipment needs, 3) anticipated start date, and 4) information about the company. Startup companies may qualify for limited-term reduced rates. Additional paperwork is required, including a Facilities Use Agreement, purchase order, and an External Affiliate appointment. This process may take a few weeks before an external user is able to start in the KNI Lab.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3334</id>
		<title>Usage Rates</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=3334"/>
		<updated>2023-10-10T21:27:23Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Caltech &amp;amp; JPL Usage Rates */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Overview of KNI Lab User Fees&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;Rates below are valid beginning October 1, 2022 and are subject to change&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* Fees are incurred on a pay-as-you-go basis (tools are charged by the hour or portion thereof).&lt;br /&gt;
* Caltech/JPL/Academic or Government lab members are &#039;&#039;&#039;NOT&#039;&#039;&#039; charged any Lab fees during days or months of non-use&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note: New users must submit a [[Membership_Forms | New User Form]] and attend general KNI Lab safety training before lab access or further tool training is allowed.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Caltech &amp;amp; JPL Usage Rates ==&lt;br /&gt;
Below is a table of &#039;&#039;direct&#039;&#039; hourly rates for lab and equipment use in the KNI Laboratory. Hourly rates are applied to an individual&#039;s actual usage in the KNI Lab. Discounted hourly rates are &amp;quot;unlocked&amp;quot; for hours that exceed the thresholds listed below. Tier C indicates the maxiumum number of hours a user will be charged in a given calendar month. Rates shown below do not include F&amp;amp;A/overhead. Overhead will be applied separately based on the PTA. Customers will be invoiced on a quarterly basis. Rates are valid beginning October 1, 2022 and are subject to change upon review at the end of FY23 Q2. &lt;br /&gt;
Rates below apply to internal Caltech or JPL users.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 80%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 50%&amp;quot;| Equipment Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 35%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15%&amp;quot; | Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | General KNI Lab Use*&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Dielectric System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford DRIE System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford III-V System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Plasmatherm Reactive Ion Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $48&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford FlexAl ALD/ALE System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford PECVD System 100&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Chalcogenide Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Dielectric Sputterer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA E-beam Evaporator (estim. Dec arrival)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| CHA MK40 E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Lesker Labline E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 600 Dualbeam Focused Ion Beam&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Atomic Force Microscope&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Atomic Force (AFM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Zeiss Orion NanoFab&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $73&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 200 NanoLab Dualbeam SEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Quanta ESEM /NPGS&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Sirion FESEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF-30 TEM, STEM, EDS &amp;amp; HAADF &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $140&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Nanoscribe Photonic Professional GT&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 3D Printer (TBA)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $12&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;General Lab Use is counted as time in the KNI cleanroom facility. It includes access to:&#039;&#039;&#039; &lt;br /&gt;
- Atomic Force Microscope (AFM)&lt;br /&gt;
- Critical Point Dryer&lt;br /&gt;
- Laser Interference Lithography System&lt;br /&gt;
- Mask Aligners&lt;br /&gt;
- Parylene Coater&lt;br /&gt;
- Profilometer&lt;br /&gt;
- Scriber Breaker&lt;br /&gt;
- Spectroscopic Ellipsometer&lt;br /&gt;
- Tube Furnaces (Wet, Dry Oxide + Annealing)&lt;br /&gt;
- Wafer Bonder&lt;br /&gt;
- Wafer Stepper&lt;br /&gt;
- Wet Chemistry Room/general chemical supplies&lt;br /&gt;
- Wire Bonder&lt;br /&gt;
- XeF2 Silicon Etcher&lt;br /&gt;
- TEM prep area (in Keck)&lt;br /&gt;
- Other tools not listed in the table above&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Miscellaneous Rates&#039;&#039;&#039;&lt;br /&gt;
*Precious Metal (gold and platinum) usage will be billed the market rate, per gram.&lt;br /&gt;
*Dedicated KNI Staff Labor/Support for Research is $100/hr.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;MONTHLY TIERED RATES&#039;&#039;&#039; &lt;br /&gt;
Discounts are applied on an individual user basis for hours accrued in a specific Lab Area during a given calendar month.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 28%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier A&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier A Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier B&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier B Hourly Rate&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot;| Tier C&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 12%&amp;quot; | Tier C Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Electron Beam Lithography (EBL)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 24 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $120&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 24-48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 48 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Etch, Reactive Ion (RIE)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 15 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $45&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 15-30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $22.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Chemical Vapor&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 10 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $60&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 10-20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Deposition, Physical&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 10 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $30&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 10-20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 20 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Focused Ion Beam (FIB)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 15 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $70&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 15-30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Scanning Electron (SEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 15 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $35&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 15-30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $17.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 30 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Microscopy, Transmission Electron (TEM)&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 16 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $130&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 16-32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $65&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| 2D/3D Print&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 50 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $15&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 50-100 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $7.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 100 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| General Lab Use&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Up to 32 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $37.50&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| 32-64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $18.75&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| Over 64 hours&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $0&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Example:&#039;&#039;&#039;&lt;br /&gt;
A lab member logs 25 cumulative hours on the Lesker e-beam evaporator and the AJA dielectric sputterer in the month of October. Based on the&lt;br /&gt;
thresholds listed above for the &amp;quot;Physical Deposition&amp;quot; Area (which includes the Lesker and AJA tools), the costs are:&lt;br /&gt;
(10 hours x $30) + (10 hours x $15) + (5 hours x $0) = $450 for 25 hours.&lt;br /&gt;
During that same calendar month, the same user logs 40 total hours in the general KNI lab facility and 5 hours on the spectroscopic ellipsometer,&lt;br /&gt;
which is included in the &amp;quot;General Lab&amp;quot; Area. Those costs are:&lt;br /&gt;
(32 hours x $37.50) + (8 hours x $18.75) = $1,350 for 40 hours.&lt;br /&gt;
The lab member&#039;s total October direct costs are $1,800.&lt;br /&gt;
&lt;br /&gt;
==OVERHEAD/INDIRECT COST RATE==&lt;br /&gt;
*Non-Caltech Academic, Government, and Corporate KNI lab members will be subject to Caltech&#039;s F&amp;amp;A (indirect/&amp;quot;overhead&amp;quot;) costs. The F&amp;amp;A rate for fiscal year 2023 is 70%. &lt;br /&gt;
Internal (Caltech and JPL) users will also have overhead applied to their charges. The overhead is accounted for in the back end of the internal charging process and the overhead rate is dependent on the PTA used to pay for the KNI Lab fees. If you have questions about this, please check with your grants manager.*&lt;br /&gt;
&lt;br /&gt;
==External/Corporate Memberships==&lt;br /&gt;
&lt;br /&gt;
For information on the KNI corporate lab membership plan, please send an email to [mailto:tkimoto@caltech.edu tkimoto@caltech.edu] with details regarding 1) the number of people looking to join as KNI lab members, 2) equipment needs, 3) anticipated start date, and 4) information about the company. Startup companies may qualify for limited-term reduced rates. Additional paperwork is required, including a Facilities Use Agreement, purchase order, and an External Affiliate appointment. This process may take a few weeks before an external user is able to start in the KNI Lab.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2779</id>
		<title>Annalena Wolff, PhD</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2779"/>
		<updated>2021-12-21T18:57:15Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|StaffPhoto = Wolff_annalena.jpg&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
===== Education =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2778</id>
		<title>Annalena Wolff, PhD</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2778"/>
		<updated>2021-12-21T18:55:19Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|StaffPhoto = Wolff_annalena.jpg&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
===== Education =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2777</id>
		<title>Annalena Wolff, PhD</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2777"/>
		<updated>2021-12-21T18:53:55Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|StaffPhoto = Wolff_annalena.jpg&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2776</id>
		<title>Annalena Wolff, PhD</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2776"/>
		<updated>2021-12-21T18:53:28Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|StaffPhoto = Wolff_annalena.jpg&lt;br /&gt;
|JobTitle = &lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2775</id>
		<title>Annalena Wolff, PhD</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2775"/>
		<updated>2021-12-21T18:52:16Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|StaffPhoto = &lt;br /&gt;
|JobTitle = &lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2774</id>
		<title>Annalena Wolff, PhD</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff,_PhD&amp;diff=2774"/>
		<updated>2021-12-21T18:51:20Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: Created page with &amp;quot;_NOTOC__ {{StaffMemberInfobox |StaffName = Annalena Wolff |StaffPhoto =  |JobTitle =  |AreasResponsibility = Microscopy |CaltechID = awolff |Phone = 626-395-5994 (office) |Off...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|StaffPhoto = &lt;br /&gt;
|JobTitle = &lt;br /&gt;
|AreasResponsibility = Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Alireza_Ghaffari&amp;diff=2761</id>
		<title>Alireza Ghaffari</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Alireza_Ghaffari&amp;diff=2761"/>
		<updated>2021-12-02T22:44:41Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: Created page with &amp;quot;__NOTOC__ {{StaffMemberInfobox |StaffName = Alireza Ghaffari |StaffPhoto = Coming Soon |JobTitle = KNI Laboratory Staff |AreasResponsibility = Foundry |CaltechID = ghaffari |P...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Alireza Ghaffari&lt;br /&gt;
|StaffPhoto = Coming Soon&lt;br /&gt;
|JobTitle = KNI Laboratory Staff&lt;br /&gt;
|AreasResponsibility = Foundry&lt;br /&gt;
|CaltechID = ghaffari&lt;br /&gt;
|Phone = 626-395-3984 (office)&lt;br /&gt;
|OfficeLocation = 176 Watson&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===== Role in the KNI =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2760</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2760"/>
		<updated>2021-12-02T22:41:41Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alireza Ghaffari&lt;br /&gt;
|JobTitle = KNI Laboratory Staff&lt;br /&gt;
|CaltechID = ghaffari&lt;br /&gt;
|Office = 176 Watson&lt;br /&gt;
|Phone = 626-395-3984 (office)&amp;lt;br&amp;gt;&lt;br /&gt;
|AreasResponsibility = Foundry&lt;br /&gt;
|Photo = Coming Soon&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Kelly McKenzie&lt;br /&gt;
|JobTitle = Laboratory Technician&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = McKenzie_Kelly_2.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = Wolff_annalena.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2759</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2759"/>
		<updated>2021-12-02T22:34:25Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alireza Ghaffari | Ghaffari, Alireza]]&lt;br /&gt;
|StaffOfficeNumber = 176 Watson&lt;br /&gt;
|StaffOfficePhone = 3984&lt;br /&gt;
|CaltechID = ghaffari&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Kelly McKenzie | McKenzie, Kelly]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Annalena Wolff | Wolff, Annalena]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5994&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2709</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2709"/>
		<updated>2021-09-23T21:27:43Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Call the Staff */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Kelly McKenzie | McKenzie, Kelly]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Annalena Wolff | Wolff, Annalena]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5994&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2708</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2708"/>
		<updated>2021-09-23T21:26:03Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Kelly McKenzie&lt;br /&gt;
|JobTitle = Laboratory Technician&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = McKenzie_Kelly_2.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = Wolff_annalena.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff&amp;diff=2675</id>
		<title>Annalena Wolff</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff&amp;diff=2675"/>
		<updated>2021-07-03T00:44:29Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff&amp;diff=2666</id>
		<title>Annalena Wolff</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff&amp;diff=2666"/>
		<updated>2021-07-02T17:06:48Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalean Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff&amp;diff=2665</id>
		<title>Annalena Wolff</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Annalena_Wolff&amp;diff=2665"/>
		<updated>2021-07-02T17:06:14Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: Created page with &amp;quot;__NOTOC__ {{StaffMemberInfobox |StaffName = Annalean Wolff |JobTitle = Microscopist |AreasResponsibility = General Lab Support |CaltechID = awolff |Phone = 626-395-5994 (offic...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Annalean Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Kelly_McKenzie&amp;diff=2664</id>
		<title>Kelly McKenzie</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Kelly_McKenzie&amp;diff=2664"/>
		<updated>2021-07-02T17:02:33Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: Created page with &amp;quot;__NOTOC__ {{StaffMemberInfobox |StaffName = Kelly McKenzie |JobTitle = Laboratory Technician |AreasResponsibility = General Lab Support |CaltechID = kmmckenz |Phone = 626-395-...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Kelly McKenzie&lt;br /&gt;
|JobTitle = Laboratory Technician&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|OfficeLocation = 130 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2660</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2660"/>
		<updated>2021-07-02T15:48:24Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Kelly McKenzie&lt;br /&gt;
|JobTitle = Laboratory Technician&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Coming soon!&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = coming soon!&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2659</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2659"/>
		<updated>2021-07-02T15:46:34Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Kelly McKenzie&lt;br /&gt;
|JobTitle = Laboratory Technician&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Coming soon!&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = coming soon!&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2658</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2658"/>
		<updated>2021-07-02T15:40:31Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nick Chacon&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Nick-chacon.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = coming soon!&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2657</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2657"/>
		<updated>2021-07-02T15:39:07Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Executive Director&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nick Chacon&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Nick-chacon.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Annalena Wolff&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = &lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2656</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2656"/>
		<updated>2021-07-02T15:37:39Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Kelly McKenzie | McKenzie, Kelly]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = kmmckenz&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Annalena Wolff | Wolff, Annalena]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5994&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2655</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2655"/>
		<updated>2021-07-02T15:34:34Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nick Chacon | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Annalena Wolff | Wolff, Annalena]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5994&lt;br /&gt;
|CaltechID = awolff&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=2608</id>
		<title>Usage Rates</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Usage_Rates&amp;diff=2608"/>
		<updated>2021-03-15T17:18:32Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Overview of KNI Lab User Fees&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;Note: Rates below are valid beginning October 1, 2020 and are subject to change&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* Fees are incurred on a pay-as-you-go basis. (tools are charged by the hour or portion thereof)&lt;br /&gt;
* Caltech/JPL/Academic or Government lab members are &#039;&#039;&#039;NOT&#039;&#039;&#039; charged any Lab fees during calendar months of non-use.&lt;br /&gt;
&lt;br /&gt;
== Caltech Academic Usage Rates ==&lt;br /&gt;
Below is a table of hourly rates for the equipment in the KNI Laboratory. Caltech/JPL users receive a quarterly fee cap for use of the cleanroom equipment in the KNI Lab. &#039;&#039;&#039;*NOTE:The maximum direct lab costs for cleanroom equipment that an individual Caltech/JPL user will be charged, per billing quarter, is $6,000.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 75%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 50%&amp;quot;| Equipment Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 35%&amp;quot;| Lab Area&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15%&amp;quot; | Hourly Rate&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Cleanroom Hourly Rate &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | General KNI Cleanroom Use&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $27.60&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Orion UHV Chalcogenide Sputter System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| AJA Orion UHV Dielectric Sputter System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| CHA MK40 E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Lesker Labline E-Beam Evaporator&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Instruments FlexAl ALD System&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford PECVD System 100&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Para Tech LabTop 3000 Parylene Coater&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Deposition, Evaporation &amp;amp; Sputtering&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $68.46&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Bruker Dimension ICON AFM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 200 NanoLab Dualbeam FIB/SEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Nova 600 Dualbeam Focused Ion Beam&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Quanta ESEM /NPGS&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Sirion FESEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF20 STEM&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| FEI Tecnai TF-30 TEM, STEM, EDS &amp;amp; HAADF &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#fec38d;&amp;quot; | Microscopy *Not Capped*&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $75.00&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Zeiss Orion NanoFab&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Microscopy&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $67.74&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford Dielectric System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $97.91&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford DRIE System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $97.91&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Oxford III-V System 100 ICP/RIE&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $97.91&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Plasmatherm Reactive Ion Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $97.91&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| XeF2 silicon etcher&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Etch&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $97.91&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5000+ Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $125.18&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Raith EBPG 5200 Electron Beam Writer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Electron Beam Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $125.18&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| GCA 6300 DSW Stepper&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Optical Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $63.82&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Heidelberg DWL-66&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Optical Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $63.82&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| NILT CNI-PV 2.1 Nanoimprint&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Optical Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $63.82&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Nanoscribe Photonic Professional GT&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Optical Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $63.82&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Suss Microtech MA6 Aligner&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Optical Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $63.82&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Suss Microtech MA6/BA6 Aligner&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Optical Lithography&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $63.82&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Dynatex GST-150 Scriber/Breaker&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Suss SB6L Wafer Bonder&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Tousimis Critical Point Dryer &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Tystar Tytan Dry Oxide + annealing&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Tystar Tytan Wet + Dry Oxide + annealing&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Westbond 7476D Wire Bonder&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#ffd8b4;&amp;quot;| Woolam M-2000 Spectroscopic Ellipsometer&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#ffe7d1;&amp;quot; | Support &amp;amp; Misc Tools&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFFFFF;&amp;quot;| $43.56&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FEE CAP EXCEPTIONS&#039;&#039;&#039; &lt;br /&gt;
*TF-30 STEM in Keck Building: Lab members who &#039;&#039;&#039;only&#039;&#039;&#039; use the TF-30 are exempt from paying the General Cleanroom hourly rate. TF-30 use does NOT qualify for the quarterly lab fee cap. Users will be billed for actual use at the hourly rate.&lt;br /&gt;
*Precious Metal (gold and platinum) usage will be billed the market rate, per gram.&lt;br /&gt;
*Dedicated KNI Staff Labor/Support for Research is $100/hr.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;OVERHEAD FEE/INDIRECT COST&#039;&#039;&#039; &lt;br /&gt;
*Rates for JPL, Non-Caltech Academic, Government, and Corporate KNI lab members will be subject to Caltech&#039;s F&amp;amp;A (indirect/&amp;quot;overhead&amp;quot;) costs. The F&amp;amp;A rate for fiscal year 2021 is 67.5%&lt;br /&gt;
&lt;br /&gt;
==Corporate Memberships==&lt;br /&gt;
&lt;br /&gt;
For information on the KNI corporate lab membership plan, please send an email to [mailto:tkimoto@caltech.edu tkimoto@caltech.edu] with details regarding 1) the number of people looking to join as KNI lab members, 2) equipment needs, 3) anticipated start date, and 4) information about the company. Startup companies may qualify for limited-term reduced rates.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2552</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2552"/>
		<updated>2020-10-19T22:47:16Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Miguel Caban-Acevedo | Caban-Acevedo, Miguel]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5994&lt;br /&gt;
|CaltechID = mcaban&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nick Chacon | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = 951-570-8458&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2551</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2551"/>
		<updated>2020-10-19T22:38:05Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nick Chacon | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = 951-570-8458&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Jennifer_Palmer&amp;diff=2550</id>
		<title>Jennifer Palmer</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Jennifer_Palmer&amp;diff=2550"/>
		<updated>2020-10-19T22:29:05Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Jennifer Palmer&lt;br /&gt;
|StaffPhoto = Jennifer-Palmer.jpg&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (Fax)&lt;br /&gt;
|OfficeLocation = 128 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;br /&gt;
Jennifer Palmer is the Administrative Lead for The Kavli Nanoscience Institute at the California Institute of Technology.  In her role she assists with billing, membership accounts, and supply purchases.&lt;br /&gt;
&lt;br /&gt;
Jennifer joined Caltech in May 2008 in the Student Housing offices of the Student Affairs Department. From there she went on to manage Caltech&#039;s Faculty Housing properties under the Facilities Department for approximately eight years. In May 2016, she transitioned to her current role at the KNI.&lt;br /&gt;
&lt;br /&gt;
===== Education =====&lt;br /&gt;
Jennifer received her B.A. in Education from Arizona State University.&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2537</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2537"/>
		<updated>2020-10-13T19:04:15Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Business Operations&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Miguel Caban-Acevedo&lt;br /&gt;
|JobTitle = Microscopist&lt;br /&gt;
|CaltechID = mcaban&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5994 (office)&lt;br /&gt;
|AreasResponsibility = SEM/FIB/TEM/Microscopy&lt;br /&gt;
|Photo = Miguel-caban-acevedo.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nick Chacon&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Nick-chacon.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2338</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2338"/>
		<updated>2020-03-19T19:59:59Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nick Chacon&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5594 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Chacon photo.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Business Operations&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2337</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2337"/>
		<updated>2020-03-19T19:49:44Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nick Chacon | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5594&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = 951-570-8458&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Nick_Chacon&amp;diff=2336</id>
		<title>Nick Chacon</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Nick_Chacon&amp;diff=2336"/>
		<updated>2020-03-19T19:44:23Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Nick Chacon&lt;br /&gt;
|StaffPhoto = Chacon photo.jpg&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Phone = 626-395-5594 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;br /&gt;
&lt;br /&gt;
===== Education =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Nick_Chacon&amp;diff=2335</id>
		<title>Nick Chacon</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Nick_Chacon&amp;diff=2335"/>
		<updated>2020-03-19T19:41:32Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Nick Chacon&lt;br /&gt;
|StaffPhoto = Chacon photo.jpg&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Phone = 626-395-5594 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;br /&gt;
&lt;br /&gt;
===== Education =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Nick_Chacon&amp;diff=2334</id>
		<title>Nick Chacon</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Nick_Chacon&amp;diff=2334"/>
		<updated>2020-03-19T19:40:22Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: Created page with &amp;quot;_NOTOC__ {{StaffMemberInfobox |StaffName = Nick Chacon |StaffPhoto = Chacon photo.jpg |JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff |AreasResponsibility = General Lab Support |Cal...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;_NOTOC__&lt;br /&gt;
{{StaffMemberInfobox&lt;br /&gt;
|StaffName = Nick Chacon&lt;br /&gt;
|StaffPhoto = Chacon photo.jpg&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Phone = 626-395-5594 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|OfficeLocation = 303 Steele&lt;br /&gt;
}}&lt;br /&gt;
== About ==&lt;br /&gt;
===== Role in the KNI =====&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2333</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2333"/>
		<updated>2020-03-19T18:55:00Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nick Chacon&lt;br /&gt;
|JobTitle = Laboratory&amp;lt;br&amp;gt;Technical Staff&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|Office = 303 Steele&lt;br /&gt;
|Phone = 626-395-5594 (office)&amp;lt;br&amp;gt;951-570-8458 (cell)&lt;br /&gt;
|AreasResponsibility = General Lab Support&lt;br /&gt;
|Photo = Chacon photo.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Business Operations&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Evan Piano&lt;br /&gt;
|JobTitle = Nanofabrication Process Engineer Intern&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = Process Development, Interim Microscopy&lt;br /&gt;
|Photo = Evan-piano.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=File:Chacon_photo.jpg&amp;diff=2332</id>
		<title>File:Chacon photo.jpg</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=File:Chacon_photo.jpg&amp;diff=2332"/>
		<updated>2020-03-19T18:52:22Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2331</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2331"/>
		<updated>2020-03-19T18:48:50Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Evan Piano | Piano, Evan]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2330</id>
		<title>KNI Staff Members</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=KNI_Staff_Members&amp;diff=2330"/>
		<updated>2020-03-19T16:48:50Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 90%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15%&amp;quot;| Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 16%&amp;quot; | Job Title&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 18%&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 14%&amp;quot;| Office &amp;amp; Phone&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 20%&amp;quot;| Areas of Responsibility&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center;&amp;quot;| Photo&lt;br /&gt;
|-&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Guy A. DeRose, PhD&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Technical Operations&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|Office = 126 Steele&lt;br /&gt;
|Phone = 626-395-3423 (office)&amp;lt;br&amp;gt;626-676-8529 (cell)&lt;br /&gt;
|AreasResponsibility = Electron Beam Lithography,&amp;lt;br&amp;gt;Lab Technical Operations&lt;br /&gt;
|Photo = Guy-A-DeRose.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Tiffany Kimoto&lt;br /&gt;
|JobTitle = Associate Director of&amp;lt;br&amp;gt;Business Operations&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|Office = 119A Steele&lt;br /&gt;
|Phone = 626-395-3914 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&amp;lt;br&amp;gt;310-291-7977 (cell)&lt;br /&gt;
|AreasResponsibility = Programs, Outreach,&amp;lt;br&amp;gt;Communications,&amp;lt;br&amp;gt;Financial Management&lt;br /&gt;
|Photo = Tiffany-Kimoto.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Bert Mendoza&lt;br /&gt;
|JobTitle = Laboratory Coordinator&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|Office = 124 Steele&lt;br /&gt;
|Phone = 626-395-4075 (office)&amp;lt;br&amp;gt;626-491-2970 (cell)&lt;br /&gt;
|AreasResponsibility = Lab Safety &amp;amp; Coordination,&amp;lt;br&amp;gt;Wet Chemistry, Photolithography&lt;br /&gt;
|Photo = Bert-Mendoza.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Jennifer Palmer&lt;br /&gt;
|JobTitle = Administrative Lead&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|Office = 128 Steele&lt;br /&gt;
|Phone = 626-395-3244 (office)&amp;lt;br&amp;gt;626-744-9908 (fax)&lt;br /&gt;
|AreasResponsibility = Accounts, Billing,&amp;lt;br&amp;gt;Purchase Orders&lt;br /&gt;
|Photo = Jennifer-Palmer.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Evan Piano&lt;br /&gt;
|JobTitle = Nanofabrication Process Engineer Intern&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|Office = 330 Steele&lt;br /&gt;
|Phone = 626-395-5732 (office)&lt;br /&gt;
|AreasResponsibility = Process Development, Interim Microscopy&lt;br /&gt;
|Photo = Evan-piano.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Nathan S. Lee&lt;br /&gt;
|JobTitle = Plasma Process Engineer&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|Office = 319 Steele&lt;br /&gt;
|Phone = 626-395-1319 (office)&lt;br /&gt;
|AreasResponsibility = Reactive Ion Etching,&amp;lt;br&amp;gt;Plasma-Enhanced CVD&lt;br /&gt;
|Photo = Nathan-S-Lee.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Alex Wertheim&lt;br /&gt;
|JobTitle = Materials Process Engineer&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|Office = 130 Steele&lt;br /&gt;
|Phone = 626-395-3371 (office)&lt;br /&gt;
|AreasResponsibility = Physical Deposition,&amp;lt;br&amp;gt;3D Printing, Ellipsometry&lt;br /&gt;
|Photo = Alex-Wertheim.jpg&lt;br /&gt;
}}&lt;br /&gt;
{{StaffMemberTableItem|&lt;br /&gt;
|Name = Patama Taweesup     &lt;br /&gt;
|JobTitle = Grants Manager&lt;br /&gt;
|CaltechID = patama&lt;br /&gt;
|Office = 142B Moore&lt;br /&gt;
|Phone = 626-395-8542 (office)&lt;br /&gt;
|AreasResponsibility = Grant Management&lt;br /&gt;
|Photo = Patama-Taweesup.jpg&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2329</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2329"/>
		<updated>2020-03-19T16:45:05Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Call the Staff */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5594&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = 951-570-8458&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Evan Piano | Piano, Evan]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2328</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2328"/>
		<updated>2020-03-19T16:40:53Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Call the Staff */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5594&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = 951-570-8458&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Evan Piano | Piano, Evan]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2327</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2327"/>
		<updated>2020-03-19T16:31:13Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: /* Call the Staff */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nick Chacon | Chacon, Nick]]&lt;br /&gt;
|StaffOfficeNumber = 303 Steele&lt;br /&gt;
|StaffOfficePhone = 5594&lt;br /&gt;
|CaltechID = nchacon&lt;br /&gt;
|StaffCellNumber = 951-570-8458&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Evan Piano | Piano, Evan]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2264</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2264"/>
		<updated>2020-02-21T19:54:29Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Barry Baker | Baker, Barry]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = bbaker5&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Evan Piano | Piano, Evan]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = empiano&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2263</id>
		<title>Lab Phone List</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Lab_Phone_List&amp;diff=2263"/>
		<updated>2020-02-21T19:52:18Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
== Caltech Emergency Number ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| Do NOT call 911&amp;lt;br&amp;gt; on campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; background-color:#FFE2B9;&amp;quot;| Emergency / Security&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot; | x5000&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; background-color:#FFE2B9;&amp;quot;| 626-395-5000&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other General Numbers ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 45%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 40%&amp;quot;| &lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot; | Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 30%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| KNI Lab-Wide General Number&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x1539&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-1539&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Security Non-Emergency&amp;lt;br&amp;gt;(card issues off-hours)&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4701&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4701&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Chemical Waste Pickup&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x6727&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-6727&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Facilities Help Desk&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4717&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4717&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Liquid Nitrogen Dewars&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4891&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4891&lt;br /&gt;
|-&lt;br /&gt;
! scope=&amp;quot;row&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Shipping &amp;amp; Receiving&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot; | x4893&lt;br /&gt;
| style=&amp;quot;text-align:center;&amp;quot;| 626-395-4893&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Lab ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 58%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 31%&amp;quot;| Room Name&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 23.3%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot; | Room Number&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Access to Cleanroom&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = AFM &lt;br /&gt;
|RoomNumber = B203B Steele&lt;br /&gt;
|PhoneNumber = x1545&lt;br /&gt;
|DialFromOffCampus = 626-395-1545&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Corridor Passthrough&lt;br /&gt;
|RoomNumber = B207CO Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Cryo STM&lt;br /&gt;
|RoomNumber = B203A Steele&lt;br /&gt;
|PhoneNumber = x1540&lt;br /&gt;
|DialFromOffCampus = 626-395-1540&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Bay&lt;br /&gt;
|RoomNumber = B235C Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Deposition Chase&lt;br /&gt;
|RoomNumber = B235B Steele&lt;br /&gt;
|PhoneNumber = x5422&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = DI Water&lt;br /&gt;
|RoomNumber = B205 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Lab&lt;br /&gt;
|RoomNumber = B225C Steele&amp;lt;br&amp;gt;B233B Steele&lt;br /&gt;
|PhoneNumber = x1531, x1540&amp;lt;br&amp;gt;or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-1531&amp;lt;br&amp;gt;-1540 or -5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = EBPG Prep&lt;br /&gt;
|RoomNumber = B225D Steele&lt;br /&gt;
|PhoneNumber = x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Elevator Passthrough&lt;br /&gt;
|RoomNumber = B224EL Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Bay&lt;br /&gt;
|RoomNumber = B235 Steele&lt;br /&gt;
|PhoneNumber = x1532&lt;br /&gt;
|DialFromOffCampus = 626-395-1532&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Etching Chase&lt;br /&gt;
|RoomNumber = B235A Steele&lt;br /&gt;
|PhoneNumber = x1533&lt;br /&gt;
|DialFromOffCampus = 626-395-1533&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gown Storage&lt;br /&gt;
|RoomNumber = B124 Steele &lt;br /&gt;
|PhoneNumber = x5938&lt;br /&gt;
|DialFromOffCampus = 626-395-5938&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Gowning Room&lt;br /&gt;
|RoomNumber = B207 Steele&lt;br /&gt;
|PhoneNumber = x1539&lt;br /&gt;
|DialFromOffCampus = 626-395-1539&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Metrology / Scriber-Breaker&lt;br /&gt;
|RoomNumber = B213 Steele&lt;br /&gt;
|PhoneNumber = x1537&lt;br /&gt;
|DialFromOffCampus = 626-395-1537&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 200 SEM/EDS&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x1542&lt;br /&gt;
|DialFromOffCampus = 626-395-1542&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Nova 600 SEM/Ga-FIB&lt;br /&gt;
|RoomNumber = B233B Steele&lt;br /&gt;
|PhoneNumber = x1534&lt;br /&gt;
|DialFromOffCampus = 626-395-1534&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = ORION He/Ne/Ga-FIB&lt;br /&gt;
|RoomNumber = B203D Steele&lt;br /&gt;
|PhoneNumber = x1548&lt;br /&gt;
|DialFromOffCampus = 626-395-1548&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith North / MA6&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1535&lt;br /&gt;
|DialFromOffCampus = 626-395-1535&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Photolith South / Bonder&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x1536&lt;br /&gt;
|DialFromOffCampus = 626-395-1536&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Quanta SEM&lt;br /&gt;
|RoomNumber =B233 Steele&lt;br /&gt;
|PhoneNumber = x5429 or x5885&lt;br /&gt;
|DialFromOffCampus = 626-395-5885&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion SEM/EDS&lt;br /&gt;
|RoomNumber = B209 Steele&lt;br /&gt;
|PhoneNumber = x1541&lt;br /&gt;
|DialFromOffCampus = 626-395-1541&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Sirion Service Chase&lt;br /&gt;
|RoomNumber = B203ME Steele&lt;br /&gt;
|PhoneNumber = x5435&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = South Lab&lt;br /&gt;
|RoomNumber = B203 Steele&lt;br /&gt;
|PhoneNumber = x5127&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Stepper&lt;br /&gt;
|RoomNumber = B217 Steele&lt;br /&gt;
|PhoneNumber = x5432&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-20 TEM&lt;br /&gt;
|RoomNumber = B203C Steele&lt;br /&gt;
|PhoneNumber = x1543&lt;br /&gt;
|DialFromOffCampus = 626-395-1543&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Tecnai TF-30 TEM&lt;br /&gt;
|RoomNumber = B242F Keck&lt;br /&gt;
|PhoneNumber = x8908&lt;br /&gt;
|DialFromOffCampus = 626-395-8908&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Video Room&lt;br /&gt;
|RoomNumber = B222A Steele&lt;br /&gt;
|PhoneNumber = x5434&lt;br /&gt;
|DialFromOffCampus = Not Available&lt;br /&gt;
}}&lt;br /&gt;
{{LabPhoneTableItem|&lt;br /&gt;
|RoomName = Wet Chemistry Room&lt;br /&gt;
|RoomNumber = B211 Steele&lt;br /&gt;
|PhoneNumber = x1538&lt;br /&gt;
|DialFromOffCampus = 626-395-1538&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Call the Staff ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;width: 85%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 21.2%&amp;quot;| KNI Staff Member&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Campus Extension&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:center; width: 15.9%&amp;quot;| Dial from Off-Campus&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 15.3%&amp;quot; | Office Number&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left;&amp;quot;| Email&lt;br /&gt;
!scope=&amp;quot;col&amp;quot; style=&amp;quot;text-align:left; width: 13%&amp;quot;| Cell&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Barry Baker | Baker, Barry]]&lt;br /&gt;
|StaffOfficeNumber = 330 Steele&lt;br /&gt;
|StaffOfficePhone = 5732&lt;br /&gt;
|CaltechID = bbaker5&lt;br /&gt;
|StaffCellNumber = &lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Guy A. DeRose, PhD | DeRose, Guy]]&lt;br /&gt;
|StaffOfficeNumber = 126 Steele&lt;br /&gt;
|StaffOfficePhone = 3423&lt;br /&gt;
|CaltechID = derose&lt;br /&gt;
|StaffCellNumber = 626-676-8529&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Tiffany Kimoto | Kimoto, Tiffany]]&lt;br /&gt;
|StaffOfficeNumber = 119A Steele&lt;br /&gt;
|StaffOfficePhone = 3914&lt;br /&gt;
|CaltechID = tkimoto&lt;br /&gt;
|StaffCellNumber = 310-291-7977&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Nathan S. Lee | Lee, Nathan]]&lt;br /&gt;
|StaffOfficeNumber = 319 Steele&lt;br /&gt;
|StaffOfficePhone = 1319&lt;br /&gt;
|CaltechID = nathslee&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Bert Mendoza | Mendoza, Bert]]&lt;br /&gt;
|StaffOfficeNumber = 124 Steele&lt;br /&gt;
|StaffOfficePhone = 4075&lt;br /&gt;
|CaltechID = bertm&lt;br /&gt;
|StaffCellNumber = 626-491-2970&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Jennifer Palmer | Palmer, Jennifer]]&lt;br /&gt;
|StaffOfficeNumber = 128 Steele&lt;br /&gt;
|StaffOfficePhone = 3244&lt;br /&gt;
|CaltechID = jpalmer&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
{{StaffPhoneTableItem|&lt;br /&gt;
|StaffName = [[Alex Wertheim | Wertheim, Alex]]&lt;br /&gt;
|StaffOfficeNumber = 130 Steele&lt;br /&gt;
|StaffOfficePhone = 3371&lt;br /&gt;
|CaltechID = alexw&lt;br /&gt;
|StaffCellNumber =&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>
	</entry>
	<entry>
		<id>https://lab.kni.caltech.edu/index.php?title=Electrical_Probing_Station&amp;diff=2262</id>
		<title>Electrical Probing Station</title>
		<link rel="alternate" type="text/html" href="https://lab.kni.caltech.edu/index.php?title=Electrical_Probing_Station&amp;diff=2262"/>
		<updated>2020-02-20T22:08:43Z</updated>

		<summary type="html">&lt;p&gt;Jpalmer: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{InstrumentInfoboxOneImage|&lt;br /&gt;
|InstrumentName = Electrical Probing Station&lt;br /&gt;
|HeaderColor = #E6E7E8&lt;br /&gt;
|ImageOne = Electrical-Probing-Station_Cascade-M150.jpg&lt;br /&gt;
|ImageTwo = &lt;br /&gt;
|InstrumentType = [[Equipment_List#Support_Tools|Support Tools]], [[Equipment_List#Metrology|Metrology]],&amp;lt;br&amp;gt;[[Equipment_List#Device_Processing|Device Processing]],&amp;lt;br&amp;gt;&lt;br /&gt;
|RoomLocation = B213 Steele&lt;br /&gt;
|LabPhone = 626-395-1537&lt;br /&gt;
|PrimaryStaff = [[Bert Mendoza]]&lt;br /&gt;
|StaffEmail = bertm@caltech.edu&lt;br /&gt;
|StaffPhone = 626-395-4075&lt;br /&gt;
|Manufacturer = Cascade Microtech&lt;br /&gt;
|Model = M150&lt;br /&gt;
|Techniques = Electrical Probing&lt;br /&gt;
|EmailList = kni-metrology&lt;br /&gt;
|EmailListName =  Metrology&lt;br /&gt;
}}&lt;br /&gt;
== Description ==&lt;br /&gt;
A manual probe station used for electrical testing of devices. Six probes are available; users are expected to supply their own probe tips. An HP4145B Parameter Analyzer is available and/or users are encouraged to bring in their own electrical equipment to use with the station.&lt;br /&gt;
===== Applications =====&lt;br /&gt;
* Miscellaneous electrical measurements&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
===== Manufacturer Resources =====&lt;br /&gt;
* [https://caltech.box.com/s/kmf1kby5d5hgmnq49x52g8vfeufbhtdq Cascade Microtech MPS150 Probe Station – Data Sheet (newer model than the one in KNI)]&lt;br /&gt;
* [https://caltech.box.com/s/xumvbal8rmyggb3h87hk0g5s8b957hqg HP4145B Parameter Analyzer – Manufacturer Manual]&lt;br /&gt;
&lt;br /&gt;
== Specifications ==&lt;br /&gt;
===== Hardware Specifications =====&lt;br /&gt;
* [https://caltech.box.com/s/kmf1kby5d5hgmnq49x52g8vfeufbhtdq Cascade Microtech MPS150 Probe Station – Data Sheet (newer model than the one in KNI)]&lt;br /&gt;
* [https://caltech.box.com/s/r65uh023p5s2tni3g3lvh7nd3mdxrfky Cascade Microtech MPS150 Probe Station – Product Highlights (newer model than the one in KNI)]&lt;/div&gt;</summary>
		<author><name>Jpalmer</name></author>